Special Offer   
£1182.00 £1066.80
(£889.00 + VAT)


10 CHANNEL ANALOGUE AUDIO WITH PRIORITY LINE

The CX10 is an audio control unit that allows a single channel priority signal to be routed into all channels of a audio system, simultaneously attenuating existing audio. The priority input gain is adjustable, also the amount of fade down of the main channels can be set. These settings are on the rear panel via recessed potentiometers. The CX1 0 also has a test facility and connections for remote monitoring. A push switch allows a quick and easy test of operation to be made.

Triggered by shorting a pair of pins on the rear panel, the CX1 0 can be linked to a fire alarm for evacuation announcements or any other requirement where 1 signal is required to take priority over all others.

Each channel level can be adjusted via recessed potentiometers behind the front panel.

Balanced inputs and outputs (that can be strapped for unbalanced operation) on all 10 channels and the priority input.

An LED on the front panel indicates when priority is triggered.

The remote monitoring facility can be used to indicate the test status and that the equipment is powered/functional.

The CX1 0 has been designed to be connected between the mixer (or pre-amp) of an audio system and the power amplifiers.

The unit may be connected to 10 channels of audio.

The priority signal (eg. emergency microphone) is connected to the priority input socket. This is a line level input. The control input is connected to the triggering device (a fire alarm or an isolated switch etc). When the unit is triggered the programme llevel in all ten channels is attenuted and the priority input automatically mixed into all ten outputs.

When the trigger is switched off or removed the programme will fade back to its original level. The amount of programme attenution is adjustable between 0 - 90 dB All controls are operated through holes in the front and rear panels for security and to avoid accidental changes to settings.

The priority signal (eg emergency microphone etc) is connected to the priority input socket. This is a line level input.

The control input is connected to the triggering device (a fire alarm or and isolated switch etc). When the unit is triggered the programme level in all ten channels is attenuted and the priority input automatically mixed into all ten outputs.

When the trigger is switched off or removed the programme will fade back to its original level.

The amount of programme attenution is adjustable between 0 - 90 dB

All controls are operated through holes in the front and rear panels for security and to avoid accidental changes to settings.

CX 10 Technical Specification

Frequency Response: 20Hz - 20Khz +/- 0.5 dB
Distortion THD+Noise: @ 1Khz Noise: O/P Level +20dBu <0.015%
Noise 20Hz - 20Khz: EIN < -90dBu

Inputs:
Electronically balanced, connect negative to screen for unbalanced use.
Input impedance: Balanced 20K Ohms
Unbalanced 10K Ohms
Maximum input level: Clip indicator: +22dBu Indicates @ +20dBu

Outputs:
Minimum load impedance: 600 Ohms
Electronically balanced, connect negative to screen for unbalanced use.
Source impedance: 100 Ohms

Controls:
Level - priority input level into all channels - rear panel
Atten - Attenuation of channels in priority mode - rear panel
1 -10 - Channel level - front panel

Attenution:
Main channels attenuate by 0 to 90dB (adjustable) on prioity

Priority input:
Input impedance> 20K Ohms, Unbalanced < 10K Ohms. Mximum input +22dBu

Control input monitoring:
Switch contacts. Close to operate. Must be isolated. Power supply monitoring via opening/closing contacts.

Visual indicators :
Power - 2 Green LED's, Priority 1 - Red LED, all on front panel

Power:
220V - 240V (110V to order).
IEC Mains connector; mains fuse 250mA slow blow.

Finish:
Front and Rear panels - Black anodised aluminium with silver legend. Case - Black plastic coated steel.

Dimensions:
19" Rack mounting, 1RU

Width 482mm (19") Depth 200mm (7.9") Height 44mm (1.75")

Download CX10 Users Instruction Manual

Rating: 4 4/5 based on 2 customer ratings
Reviews

Formula Sound CX10 Priority / Evacuation System - formulasounddirect.com



Formula Sound News Headlines

garment-smv-calculator added to PyPI 2026-04-28
SMV (Standard Minute Value) calculator for garment industry sewing operations. formula: SMV = Basic Time x (1 + Allowance%). Built and used in production by Scan ERP.
F1 Legend Sebastian Vettel Just Ran the London Marathon in a Miraculous Time For Charity 2026-04-27
A four-time formula 1 world champion who spent two decades training his body to sit very still inside a very loud machine has, it turns out, also been quietly putting in the running miles. Sebastian Vettel completed his first ever…
Timberwolves dominated by Denver in Game 5 blowout loss 2026-04-28
DENVER — Minnesota has a path to beat Denver, even without Anthony Edwards and Donte DiVincenzo. But the formula involves doing almost none of the things the Timberwolves put forth in Game 5 in Denver. With a chance to close out the series, Minnesota was slop…

See the FF6000 in action


Wednesday 29 April 2026