FSD

Formula Sound Professional Audio Mixers
  Find us on Facebook
Class Leading
Products
From The Name
You Trust
Free Delivery on most UK orders
Basket more
Basket Empty
  Home »

Noise Control

»

CX10 Priority / Evacuation System

My Account  |  Basket (empty)  |  Checkout   
×

CX10 Priority / Evacuation System

Special Offer   
£1182.00 £1020.00
(£850.00 + VAT)


10 CHANNEL ANALOGUE AUDIO WITH PRIORITY LINE

The CX10 is an audio control unit that allows a single channel priority signal to be routed into all channels of a audio system, simultaneously attenuating existing audio. The priority input gain is adjustable, also the amount of fade down of the main channels can be set. These settings are on the rear panel via recessed potentiometers. The CX1 0 also has a test facility and connections for remote monitoring. A push switch allows a quick and easy test of operation to be made.

Triggered by shorting a pair of pins on the rear panel, the CX1 0 can be linked to a fire alarm for evacuation announcements or any other requirement where 1 signal is required to take priority over all others.

Each channel level can be adjusted via recessed potentiometers behind the front panel.

Balanced inputs and outputs (that can be strapped for unbalanced operation) on all 10 channels and the priority input.

An LED on the front panel indicates when priority is triggered.

The remote monitoring facility can be used to indicate the test status and that the equipment is powered/functional.

The CX1 0 has been designed to be connected between the mixer (or pre-amp) of an audio system and the power amplifiers.

The unit may be connected to 10 channels of audio.

The priority signal (eg. emergency microphone) is connected to the priority input socket. This is a line level input. The control input is connected to the triggering device (a fire alarm or an isolated switch etc). When the unit is triggered the programme llevel in all ten channels is attenuted and the priority input automatically mixed into all ten outputs.

When the trigger is switched off or removed the programme will fade back to its original level. The amount of programme attenution is adjustable between 0 - 90 dB All controls are operated through holes in the front and rear panels for security and to avoid accidental changes to settings.

The priority signal (eg emergency microphone etc) is connected to the priority input socket. This is a line level input.

The control input is connected to the triggering device (a fire alarm or and isolated switch etc). When the unit is triggered the programme level in all ten channels is attenuted and the priority input automatically mixed into all ten outputs.

When the trigger is switched off or removed the programme will fade back to its original level.

The amount of programme attenution is adjustable between 0 - 90 dB

All controls are operated through holes in the front and rear panels for security and to avoid accidental changes to settings.

CX 10 Technical Specification

Frequency Response: 20Hz - 20Khz +/- 0.5 dB
Distortion THD+Noise: @ 1Khz Noise: O/P Level +20dBu <0.015%
Noise 20Hz - 20Khz: EIN < -90dBu

Inputs:
Electronically balanced, connect negative to screen for unbalanced use.
Input impedance: Balanced 20K Ohms
Unbalanced 10K Ohms
Maximum input level: Clip indicator: +22dBu Indicates @ +20dBu

Outputs:
Minimum load impedance: 600 Ohms
Electronically balanced, connect negative to screen for unbalanced use.
Source impedance: 100 Ohms

Controls:
Level - priority input level into all channels - rear panel
Atten - Attenuation of channels in priority mode - rear panel
1 -10 - Channel level - front panel

Attenution:
Main channels attenuate by 0 to 90dB (adjustable) on prioity

Priority input:
Input impedance> 20K Ohms, Unbalanced < 10K Ohms. Mximum input +22dBu

Control input monitoring:
Switch contacts. Close to operate. Must be isolated. Power supply monitoring via opening/closing contacts.

Visual indicators :
Power - 2 Green LED's, Priority 1 - Red LED, all on front panel

Power:
220V - 240V (110V to order).
IEC Mains connector; mains fuse 250mA slow blow.

Finish:
Front and Rear panels - Black anodised aluminium with silver legend. Case - Black plastic coated steel.

Dimensions:
19" Rack mounting, 1RU

Width 482mm (19") Depth 200mm (7.9") Height 44mm (1.75")

Download CX10 Users Instruction Manual

Rating: 4 4/5 based on 2 customer ratings
Reviews

Formula Sound CX10 Priority / Evacuation System - formulasounddirect.com



Formula Sound News Headlines

Everything is a bonus for relaxed Verstappen 2025-12-04
ABU DHABI, Dec 4 : Max Verstappen could become only the second driver after Michael Schumacher to win five formula One titles in a row this weekend but the Red Bull driver was relaxed about it on Thursday.Neither parent will be in attendance in Abu Dhabi - fa…
McLaren hasn't discussed F1 team orders for Abu Dhabi; Norris won't ask for them 2025-12-04
McLaren has not discussed any team orders ahead of formula 1's title crescendo at the Abu Dhabi Grand Prix - and current championship leader Lando Norris says that he won't ask for them to help his cause.The championship is finely poised ahead of the 2025 sea…
Haas boosts Toyota ties with F1 title partnership 2025-12-04
Haas has signed a landmark title partnership deal with Toyota for the 2026 formula 1 world championship, with the team becoming known as TGR Haas F1 Team.The deal is the next stage in the strengthening ties between the American F1 outfit and the Japanese auto…

See the FF6000 in action


Friday 05 December 2025