10 CHANNEL ANALOGUE AUDIO WITH PRIORITY LINE

The CX10 is an audio control unit that allows a single channel priority signal to be routed into all channels of a audio system, simultaneously attenuating existing audio. The priority input gain is adjustable, also the amount of fade down of the main channels can be set. These settings are on the rear panel via recessed potentiometers. The CX1 0 also has a test facility and connections for remote monitoring. A push switch allows a quick and easy test of operation to be made.

Triggered by shorting a pair of pins on the rear panel, the CX1 0 can be linked to a fire alarm for evacuation announcements or any other requirement where 1 signal is required to take priority over all others.

Each channel level can be adjusted via recessed potentiometers behind the front panel.

Balanced inputs and outputs (that can be strapped for unbalanced operation) on all 10 channels and the priority input.

An LED on the front panel indicates when priority is triggered.

The remote monitoring facility can be used to indicate the test status and that the equipment is powered/functional.

The CX1 0 has been designed to be connected between the mixer (or pre-amp) of an audio system and the power amplifiers.

The unit may be connected to 10 channels of audio.

The priority signal (eg. emergency microphone) is connected to the priority input socket. This is a line level input. The control input is connected to the triggering device (a fire alarm or an isolated switch etc). When the unit is triggered the programme llevel in all ten channels is attenuted and the priority input automatically mixed into all ten outputs.

When the trigger is switched off or removed the programme will fade back to its original level. The amount of programme attenution is adjustable between 0 - 90 dB All controls are operated through holes in the front and rear panels for security and to avoid accidental changes to settings.

The priority signal (eg emergency microphone etc) is connected to the priority input socket. This is a line level input.

The control input is connected to the triggering device (a fire alarm or and isolated switch etc). When the unit is triggered the programme level in all ten channels is attenuted and the priority input automatically mixed into all ten outputs.

When the trigger is switched off or removed the programme will fade back to its original level.

The amount of programme attenution is adjustable between 0 - 90 dB

All controls are operated through holes in the front and rear panels for security and to avoid accidental changes to settings.

CX 10 Technical Specification

Frequency Response: 20Hz - 20Khz +/- 0.5 dB
Distortion THD+Noise: @ 1Khz Noise: O/P Level +20dBu <0.015%
Noise 20Hz - 20Khz: EIN < -90dBu

Inputs:
Electronically balanced, connect negative to screen for unbalanced use.
Input impedance: Balanced 20K Ohms
Unbalanced 10K Ohms
Maximum input level: Clip indicator: +22dBu Indicates @ +20dBu

Outputs:
Minimum load impedance: 600 Ohms
Electronically balanced, connect negative to screen for unbalanced use.
Source impedance: 100 Ohms

Controls:
Level - priority input level into all channels - rear panel
Atten - Attenuation of channels in priority mode - rear panel
1 -10 - Channel level - front panel

Attenution:
Main channels attenuate by 0 to 90dB (adjustable) on prioity

Priority input:
Input impedance> 20K Ohms, Unbalanced < 10K Ohms. Mximum input +22dBu

Control input monitoring:
Switch contacts. Close to operate. Must be isolated. Power supply monitoring via opening/closing contacts.

Visual indicators :
Power - 2 Green LED's, Priority 1 - Red LED, all on front panel

Power:
220V - 240V (110V to order).
IEC Mains connector; mains fuse 250mA slow blow.

Finish:
Front and Rear panels - Black anodised aluminium with silver legend. Case - Black plastic coated steel.

Dimensions:
19" Rack mounting, 1RU

Width 482mm (19") Depth 200mm (7.9") Height 44mm (1.75")

Download CX10 Users Instruction Manual

Rating: 4 4/5 based on 2 customer ratings
Reviews

Formula Sound CX10 Priority / Evacuation System - formulasounddirect.com



Formula Sound News Headlines

Ferrari fastest as Verstappen says Kiwi rival should 'act a little smarter' 2026-10-31
Ferrari's Charles Leclerc was fastest in both practice sessions for a Mexico City Grand Prix set to crown 20-year-old Mercedes driver Kimi Antonelli as formula 1's youngest champion.
F1 Mexico GP: Leclerc beats Antonelli to top FP1 2026-10-30
Charles Leclerc was comfortably fastest in opening practice for the formula 1 Mexico Grand Prix, beating runner-up Kimi Antonelli in a session 10 rookies took part in.The Ferrari driver set a 1m18.128s that was six tenths faster than formula 1’s champion-elec…
The confusion surrounding Colton Herta's F1 superlicence explained 2026-10-30
After completing more than 100 kilometres during the first free practice session at the Mexico Grand Prix, Colton Herta appeared to have 40 superlicence points to his name, which would be enough to qualify for the document required to secure a formula 1 seat.…

See the FF6000 in action


Monday 02 November 2026